- NO FLUCTUATIONS AND FAILURES IN THE POWER SUPPLYUPS DEVICES
BORRI AND ABLEREXwithout interruptions of the power supply
Single-phase UPS devicesUPSABLEREX
Монофазните UPS са подходящи за много приложения, включително малки офиси, банкомати и магазини, малки и средни предприятия, сървърни помещения, инфраструктурни и леки индустриални приложения.
Three-phase UPS devicesUPSBORRI
Трифазните UPS устройства са идеалното решение за непрекъснато електрозахранване, осигурявайки постоянно и безкомпромисно захранване на бизнес операциите. Те гарантират надеждно електрозахранване.
UPS device ABLEREX MARS III Т 6000VA/6000W
TECNOLOGY: ONLINE, DOUBLE CONVERSION
POWER FACTOR: 1.0
POWER: 6000VA/6000W
PRICE: BGN 1,260 ( VAT inclusive)




USAGE

SHOP
HOTEL

SMALL
OFFICE

HOSPITALS
MEDICAL CENTERS

INDUSTRIAL
PLANTS

SERVER
RACKS

CCTV
SURVEILLANCE
TECHNICAL DATASHEET
ABLEREX MARS III Т 6000VA/6000W
Suitable for:
Any kind of precision single phase equipment, intolerant of power outages.
Description:
MSIII Tower has a number of smart features that increase battery lifespan. Thanks to the new battery discharge protection control function, it is ideal for applications even in medium voltage substations. This product belongs to the family of Ablerex Single Phase UPS systems.
Advantages:
- Top class UPS unit: pure sine wave online technology
- Online VFI protection with double conversion with maximum power – 6000VA=6000W.
- Option for parallel work of up to 4 (four) devices (24kW)
- Exceptional battery life thanks to wide input voltage tolerance (110-280V) – wide input frequency tolerance (45-70Hz) – intelligent battery management.
- Battery discharge level control, adjustable 30-100% of available capacity.
- Accurate, patented backup time estimation.
- Cold start to activate unpowered loads.
- Option to add up one or more external boxes, allowing a significant increase in reserve time, if necessary.
- 6-stages functionality test enabled.
- Multiple operating modes to maximize energy efficiency.
- Manually activated additional service check.
- Multiple communication options with all major PC operating systems
Specifications:
- Power: 6000VA/6000W
- Input voltage: 110–280 Vac
- Output voltage: 200/208/220/230/240 Vac
- Frequency: 50/60 Hz (optional)
- Power factor: 1.0
- Input/Output: fixed
- Dimensions (WxDxH), mm: 240x700x513
- Weight, kg: 53
- Alarms (audio and screen): loss of power, low battery charge, switching to bypass, technical errors
- Protections: Overvoltage, Overheat, Short Circuit, Deep Discharge, Battery Overcharge
- Battery type: 12V VRLA, AGM (no maintenance needed)
- Batteries number: 16
- Reserve time (min): at 50% load: 12, at 100% load: 4
- Additional reserve time: with external battery boxes. Box size (WxDxH), mm: 288x663x661
- Battery charging time (90%): 4 hours
- Operating environment temperature: 0–40°C
- Maximum noise (up to 1 m.): ≤60 dBA
- Communication ports: USB, RS232, EPO, plus an additional slot for other cards
- User interface: LED, LCD and function buttons. Parameters: voltage, frequency, charge percentage, battery voltage, output voltage, estimated reserve time (according to the load), device temperature.
- Additional communication options available: SNMP, RS485 ModBus and relay contacts
- Compatible operating systems: Microsoft Windows, Linux, Mac OS, VMware
- Standards: IEC EN 62040-1, IEC EN 62040-2, IEC EN 62040-3
Availability: yes, in stock
Delivery term: Sofia, order up to 1 p.m.: today, Sofia after 1p.m. and country: tomorrow
- OPPORTUNITY TO RENT A UPS DEVICE
- OPPORTUNITY FOR OPERATING LEASING OF UPS DEVICE
We, the engineering team at Power Backup, offer warranty support for our machines – it is our primary duty and we fulfill it unconditionally and flawlessly. Therefore, each of our projects ends not with the installation of our equipment, but two years later – with the expiration of the warranty period. Following this philosophy, we receive the highest marks from our clients for proven proficiency.
The wise and productive lifespan of the devices goes far beyond the warranty period and we know that the better they are maintained, the longer they will serve you. Post-warranty support is a smart and strategic approach to protect the investment made. We offer a wide range of services in the form of subscription maintenance or ad-hoc support, thus ensuring monitoring of devices and timely resolution of potential problems.
Checking a UPS device or system is based on a long checklist of functionality and component checks & probes. Specific tests are done on the batteries as well. The batteries are measured individually – one by one, their connections are checked, and specific cleaning actions are carried out.
Timely maintenance is the most efficient prevention which will protect you from the hypothesis of finding out that your device is not functional just when it should perform its main function.
The batteries are the most critical component of the UPS device. They also form a significant part of its value. Batteries have a certain useful lifespan and then after they should be replaced. This period depends significantly on the environment in which the UPS device works, the number of events of battery discharge and especially – the number of events of deep discharge.
It is extremely important to use quality batteries. High quality batteries ensure seamless operations of the device. For many reasons, such as fact that even one defective battery completely compromises the device’s performance. Quality batteries are also able to presume stressful events of discharges adequately. And last but not least, quality batteries have a number of protections against burning and fire – a problem that is not as common with traction VRLA batteries as with lithium-ion technology, but still is not excluded in poor operating conditions and various types of accidents.
In terms of longevity and reliability, quality batteries are significantly more cost-efficient than mid-and low-range brands.
We are commercial representative of leading brands of quality batteries (FIAMM, CSB and others), we are professionally prepared for any kind of batteries replacement. Give us a call and ask how we can help with batteries.
ABLEREX MARS III Т 6000VA/6000W – download PDF file
USEFUL INFORMATION
Types of UPS devices
There are two main classes of UPS devices according to the technology used: The basic one uses the “Line Interactive” technology. Such devices are also called “protectors” and are primarily used to protect consumer equipment. The high-end, professional class uses “Online” technology, with the best having a pure double-conversion sine wave.
UPS functions
The function of the UPS device (uninterruptible power supply) is to ensure an uninterrupted supply of power to the consumer equipment. UPS devices are not an emergency power source (the power generators are). They serve to provide temporary power (usually from 1 to 5 minutes) – until the replacement of the main power source with an emergency one is established.
In some cases, when there is no emergency power source (power genset), the UPS unit could perform this function. Still there are two options to ensure longer period of autonomy; either more powerful UPS than need from consumer to be used or additional battery boxes to be installed.
UPS batteries
Batteries are the “heart” of the UPS device and form a significant part of its value. They should be properly selected and maintained. Batteries have a certain period of life, after which they should be replaced.
UPS battery support
Proper battery maintenance ensures seamless use of the UPS device at its full capacity. Batteries life stages: they reach their maximum capacity after 3 discharge/charge cycles, after which they begin to slowly lose their qualities (thus reserved time goes slowly down). The main indicator of the “health” of batteries is their internal resistance. Regular monitoring of the resistance (by measuring each battery) gives a clear picture of the state of the batteries and allows promptly on-time replacement in the event of a problem.
UPS battery discharge
Deep discharge is a state of using more than 70%-80% of the battery capacity. Any achievement of a deep discharge condition substantially reduces the useful lifespan of the batteries. Most hi-end devices have built-in deep charge protection functionalities and cut off the supply of power to the consumer when the output voltage from the batteries drops down to levels of 10.8-10.5 Vac. The guaranteed autonomy time at the corresponding load, provided as an indicator by the manufacturer in the technical spreadsheet, indicates the period of discharge of the batteries from 100% until the moment of protective shutdown due to potential deep discharge.
When discharged, batteries release heat. Therefore, it is very important that the industrial UPS devices work in air-conditioned rooms, with the air conditioners also being reserved. The optimal temperature environment (16-20°C) ensures trouble-free operation of the device and longer battery life. On the contrary: if the batteries are in an aggressive environment (above 30°C), their life is significantly shortened and there is a risk of fire.